CONTA-ELECTRONICS
===== = = = = = = = = =
CMS
CMSCMS
CMS-
--
-UI
UIUI
UI-
--
-R
RR
R=
=====
==========
=====I
II
Isolated
solatedsolated
solated S
S S
Signal
ignalignal
ignal
converter
converterconverter
converter
Further information: www.conta-clip.com Cat. No.: 95120.8
Further information: www.conta-clip.com
Electrical specifications
Electrical specificationsElectrical specifications
Electrical specifications
Manual
ManualManual
Manual
=
=
=
=
The CMS-UI-R is a multi-functional 3-way isolated
threshold relay. This module is used for control and
alarm functions.
The 3-way isolation enables the module to be used
locally as well as in the vicinity of the controlling
system.
The inputs and output relay functions of the converter
are configured by means of dipswitches.
Any combination of input and output can be chosen,
so numerous different control functions can be set.
Default input/output relay setting is 0..10V / threshold
with hysteresis.
Other default input/output settings on request.=
=
Order information
Order informationOrder information
Order information
type CMS-UI-R
cat.no 95120.8
Input data
Input dataInput data
Input data
range (select via dipswitches) 0-1V/0-2V/0-2,5V/0-5V/1-5V/0-10V/0-20V/0-40V/0-5mA/0-10mA/0-20mA/4-20mA
max. input signal (U / I) 40V / 25mA
input resistance (U / I) > 200 kOhm / 50 Ohm
Output data
Output dataOutput data
Output data
relay output 1CO contact, 240V~
output function (select via dipswitch) threshold with hysteresis / ON and OFF threshold / threshold range control
adjustment range Threshold / Hysteresis 10…90%
rated / inrush current (ohmic load) 3A / 5A
max. power rating 1200VA @ 240V ac, 5A
life span @ 23°C and ohmic load
Electrical: at rated load: > 1,5 x 10
contact material AgNi
test voltage 4kV
General data
General dataGeneral data
General data
module power supply 24V DC ±25%
module current Approx. 50mA
temperature coefficient < 0,02 %/°C
max. conversion frequency 10Hz
CE marking Low Voltage Directive (LVD) 2006/95/EC, according requirements of EN 61010
EMC Directive 2004/108/EC, according requirements of EN 55011 and EN 61326-1
isolation voltage input / power 1kV, 50Hz, 1min.
isolation voltage input / output 4kV
isolation voltage output / power 4kV
operating / storage temperature 0°C…+55°C / -20°C…+70°C
conductor cross section 0,2 - 2,5 mm²
connection system screw clamp connection, pluggable
insulation stripping length 7 mm
mounting / installation position DIN-rail TS35 / any
module size LxWxH (TS35) 17,5 x 99 x 114,5mm
weight 120 gr
Features:
Features:Features:
Features:
• Multifunctional analog input (0..1V, 0..2V, 0..2,5V, 0..5V, 1..5V, 0..10V, 0..20V,
0..40V, 0..5mA, 0..10mA, 0..20mA, 4..20mA)
• 3 output relay control functions (threshold with hysteresis, ON and OFF threshold,
threshold range control)
• Analog signal range selectable via DIP switches
• 3-Way galvanic isolation
• Power supply 24V DC
• Other analog signal ranges on request